Brand Name: | KIC |
Model Number: | X5 |
MOQ: | 1 pc |
Price: | Negotiable |
Payment Terms: | T/T, Western Union |
Supply Ability: | 500pcs per month |
KIC2000 Compact, Robust Thermal Profiler for SPC Charting
Features
1, Transmit reception frequency: 433.92MHz
2, Full Original Package, with original Thermal Couples, Protective Shield, Software, etc
3, Technical Support and Warranty from USA
4, Thermal Process Optimization for Lower Energy Use
5, Standard SPC charting software include CpK, Help reveal change in the profile over time
6, Standard Profile Overlay, show different process.
7, Robust and Compact Hardware with 1 year warranty
8, 9 and 12 Channels (Standard Type K TC connectors)
Specifications
Accuracy | ±1.2°C |
Resolution | Variable 0.3 to 0.1°C |
Internal Operating Temp | 0°C to 105°C |
Thermocouple Compatibility | Type K, 9 or 12 TCs |
Temperature Range | -150°C to 1050°C |
Computer Capability | PC |
Power Requirements | 9V alkaline battery |
Thermal Receiver | 433.92 MHz |
Dimensions | See Temperature Tolerance Chart below for specifications. |
Operating Methods
1.Firstly, check whether the battery power is sufficient, if it is lower than 20% you have to charge it first, secondly, if the surface temperature of the instrument is higher than 45℃C please don't charge it, try to charge it at room temperature.
2. Typical causes of problems when establishing communication links:Communication cable not fully inserted - make sure the correct jack is used. Communication cable or connector is damaged - check for breaks or other damage. Battery is not charging I Charge. and make sure the charging LED is on.
3. The thermal barrier can withstand a maximum of 9 minutes at 280° C. Be sure to exceed this range and ensure that the internal temperature of the instrument does not exceed 85° C.
4. When not in use for a long time, please observe whether the data indicator light flashes every 5 seconds or so, if it does, please press and hold down the "start" end key for about 5 seconds until the indicator light suddenly flashes, and then observe it until there is no light flashing.
5. Please make sure to cover the heat insulation box when crossing the furnace, and wait for the time to arrive.
6. You can only connect one Oven Tester logger to the computer at a time. Can not be connected to the computer at the same time more than one recorder to the same USB port and then choose one of them.
7. After a furnace again over the furnace, and so on the thermal barrier box cooled down before use.